Siemens HiPath 5000 Service Manual page 636

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Distribution of the PCM segments
There are 64 time-division multiplex channels available for each PCM segment. Blockages oc-
cur if these are busy. The system cannot execute any more call requests.
To guarantee that the system operates without blocking, make sure when you perform config-
uration that the boards on a PCM segment do not require more than the 64 time-division mul-
tiplex channels that are available. The following table lists the number of time-division multiplex
channels that the different boards require.
Table 4-16
Number of Time-Division Multiplex Channels Required Per Board
Board
CR8N
HXGM3 (without extension
modules for additional DSP
channels)
IVML8
IVML24
SLA8N, SLA16N, and
SLA24N
SLC16N
SLMO8, SLMO24
STMD8
TIEL
TMDID8
TML8W
TMS2
TMST1
4-158
Number of time-division multiplex channels required
8
16
8
24
Depends on the number of stations
Depends on the number of mobile telephones logged on
Depends on the number of stations (hosts (master) and clients
(slave))
16
4
8
8
30
24
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual