Inserting or Removing Boards

Introduction
Peripheral boards can be inserted and removed while the power is connected. Two levers are
attached to the front corners of the boards to simplify insertion and removal. When closed,
these levers engage with the board, locking it in place.
See Section 9.2.2 for information on upgrading peripheral boards.
Procedure for inserting and removing the boards (Figure 4-93)
If
Boards
Swing both plastic levers outward simultaneously. You can now pull the board
Unlocking the
out of the system on its guide rails.
board
(1)
Boards
Slide the board into the system using its guide rails. Insert the hooks on the
Latching as-
locking levers into the recesses in the shelf. Press down on both levers simul-
sembly
taneously in the direction of the shelf until they snap into place.
(2)
Locking and Unlocking Boards
(1)
(2)
(2)
(1)
Figure 4-93
Locking and unlocking boards
Special board attachments
The power supply is screwed onto the grill of each cabinet.