Boards for HiPath 3000
Peripheral Boards
3.3.10

PBXXX (for selected countries only)

Introduction
The PBXXX (Peripheral Board XXX) module can be used in HiPath 3800 to support country-
specific CAS protocols.
The peripheral board slots on the HiPath 3800 are fitted with SIPAC 9 SU connec-
>
tors. Since the PBXXX2 board has SIVAPAC connector strips, you will have to install
a SIVAPAC-SIPAC board adapter in order to be able to use it in HiPath 3800.
For information on this procedure, please see Section 4.2.5.4.
The PBXXX board converts the Euro-ISDN protocol on an S
Signaling (CAS) protocol. The board functions only in conjunction with a DIUN2. There is no
direct connection between the PBXXX board and the system's central control unit. The DIUN2
handles all signaling and data traffic.
The following combination options are possible:
1 x DIUN2 + 1 x PBXXX (see Page 3-139)
The PBXXX board must be plugged in on the left next to the DIUN2.
1 x DIUN2 + 2 x PBXXX (see Page 3-142)
The PBXXX boards must be plugged in on the left and right next to the DIUN2.
Up to four PBXXX boards can be installed in a HiPath 3800. For power supply reasons, a max-
imum of two PBXXX can be installed in a cabinet.
Administration of the CAS protocol converter
Use the ECGM tool for administration. For information on installing the software on the service
PC and on the required settings, see Page 3-293.
The C39195-Z7267-C2 cable can be used with a C39334-Z7080-C2 adapter (9-pin Sub-D jack
– 25-pin Sub-D jack) to connect the PBXXX (port M) and the service PC.
Notes on setup using HiPath 3000 Manager E
Because the PBXXX card is not recognized by the hardware, offline configuration is required
with HiPath 3000 Manager E. Either "DIUN2 + PBXXX" or "DIUN2 + 2PBXXX" should be spec-
ified as the board to be configured. After configuration, the module data can be seen in HiPath
3000 Manager E. However, this is only visible in the software configuration, as the PBXXX card
was only configured on the software side.
Note: The offline configuration of the PBXXX serves solely to visualize the card with HiPath
3000 Manager E.
3-136
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
link into the Channel Associated
2M
P31003-H3560-S403-54-7620, 09/05