3.2.2

CBRC

Introduction
The CBRC board (Central Board Rack Com, S30810-Q2935-Z301) performs all central control
and switching functions for HiPath 3500 and HiPath 3300 (see Figure 3-2).
The CBRC central control board needs to be replaced for HiPath 3000 V6.0. The
>
CBRC board (S30810-Q2935-Z301) is required.
The "old" CBRC board S30810-K2935-Z is not supported.
Subboards
The following subboards can be used depending on the application:
Clock module
CMA
MMC
multimedia card
IMODN
integrated modem card new (optional)
LIM
LAN interface module (optional)
MPPI
music on hold (optional)
EVM
entry voice mail (optional)
Outputs, interfaces
Eight digital U
P0/E
For example, U
be connected here.
Four analog T/R subscriber lines
For U.S. only: These interfaces do not support the connection of external extensions via
OPS (Off-Premises Station) signaling.
For Australia only: The T/R interfaces supply a ring voltage of 35 V
terminals connected, we cannot exclude the possibility of errors occurring during ringing
state.
Two digital S
interfaces (CO (default) or station)
0
Backplane (CUCR or CUPR) connection via slots 1 (X11), 2 (X5) and 3 (X6)
Music on hold: MPPI, EXMR
Options bus (O bus)
V.24 interface
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
or
CMS
(optional)
subscriber lines
workpoint clients or BS3/1 base stations for HiPath Cordless Office can
P0/E
boards.fm
Boards for HiPath 3000
Central Boards
. Depending on the
eff
3-25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800

Table of Contents