Migration Of Two-Dimensional Gud Tags With Column Tag - Siemens sinumerik 840d sl Configuration Manual

Sinumerik integrate create myhmi / wincc v13 sp1
Hide thumbs Also See for sinumerik 840d sl:
Table of Contents

Advertisement

3.7

Migration of two-dimensional GUD tags with column tag

Migrated two-dimensional GUD tags for which an index tag has been configured as
"Column" in WinCC flexible cannot be modified in the TIA Portal.
As can be seen in the screenshot, this index tag is entered in the "Column" field and grayed
out (cannot be edited) after migration of such a tag.
Figure 3-4
However, no index tags are allowed in the "Column" field in the TIA Portal, only fixed
numbers. The position of these GUD tags in the DEF file for this GUD group must be in the
"Column" field.
● If a fixed value is entered in the "Column" field after migration, this value is correctly
adjusted when the tags are transferred to the TIA Portal.
● If there is a tag in the "Column" field after migration, it cannot be changed in the TIA
Portal. In this case, delete the GUD tag and create a new one.
There can be a tag in the "Row" field in the TIA Portal; this tag then determines the
linearized GUD array element.
See also: Configuration of GUD arrays (Page 76)
SINUMERIK Integrate Create MyHMI / WinCC V13 SP1
Configuration Manual, 11/2014
3.7 Migration of two-dimensional GUD tags with column tag
Migrated GUD tag with tag in the "Column" field
Migrating HMI projects
41