Cautions
1. Devices specified in
• In a 32-bit operation (by DMUL or DMULP), Z cannot be specified in
2. When monitoring the operation result in a programming tool
Even if word devices are used, the operation result (64 bits) cannot be monitored at one time.
In such a case, floating point operation is recommended.
Program examples
1. 16-bit operation
X000
FNC 22
MUL
2. 32-bit operation
X001
FNC 22
DMUL
Function Changes According to Versions
FX
3G
Ver. 1.00 or later
278
D
S1
S2
D
D 0
D 2
D 4
S1
S2
D 0
D 2
D 4
Compatible Versions
FX
FX
3U
Ver. 2.30 or later
Ver. 2.30 or later
10 Arithmetic and Logical Operation (+, −, ×, ÷) – FNC 20 to FNC 29
→ For the floating point operation, refer to Chapter 18.
(D 0) × (D 2) → (D 5,D 4)
8
9
D
(D 1,D 0) × (D 3,D 2) → (D 7,D 6,D 5,D 4)
1756
327
Item
3UC
Turns the special device M8304 ON when the
Zero Flag
operation result of MUL command is 0.
10.3 FNC 22 – MUL / Multiplication