Mitsubishi Electric FX3G SERIES Programming Manual page 357

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
6. Priority order in operations among HSCS (FNC 53), HSCR (FNC 54), and HSZ (FNC 55)
instructions for the same high-speed counter
1)
FX
/FX
PLC
3U
3UC
When the same comparison value is used for the same high-speed counter in the HSCS, HSCR and HSZ
instructions, reset (self-reset) of the comparison target high-speed counter for the HSCR instruction is executed
with the highest priority (as shown in the table below).
In this case, the comparison results do not change in HSCS, HSCR, and HSZ instructions whose comparison
value is programmed to be the same as the comparison value for self-reset by HSCR instruction.
To change the comparison results, set the comparison value to "K0".
2)
FX
PLCs
3G
In FX
PLCs, the HSCS, HSCR and HSZ instructions are executed in the order of programming.
3G
M8000
M8000
FNC 55
DHSZ
FNC 11
DZCPP
M8000
Operation of FX
/FX
3U
3UC
Present value
500
250
0
Y000 to Y002 and Y006 do not change.
Y003
ON
ON
Y004
OFF
It does not change.
OFF
Y005
*1.
To change the comparison results by the instructions (1)
to (3) and (5), change the comparison value "K500" in the
instructions (1) to (3) and (5) to "K0".
*2.
To set Y005 to ON in the HSZ instruction (4), set a value
smaller than the comparison value "K500". However, due
to the response delay at the output, the output may not
operate within the short time before the counter's present
value is reset to "0".
C235
K10000
FNC 53
K500
C235
Y000
DHSCS
FNC 53
K500
C235
Y001
DHSCS
FNC 54
K500
C235
Y002
DHSCR
K250
K500
C235
Y003
K250
K500
C235
Y003
FNC 54
K500
C235
Y006
DHSCR
FNC 54
K500
C235
C235
DHSCR
Self-reset program
PLC
*1
*2
13 High-Speed Processing – FNC 50 to FNC 59
13.4 FNC 53 – HSCS / High-Speed Counter Set
Program
sequence
FX
/FX
3U
DHSCR (6)
DHSCS (1)
(1)
(self-reset)
DHSCS (2)
DHSZ (4)
DHSCR (3)
DHSCS (1)
(2)
DHSZ (4)
DHSCS (2)
DHSCR (5)
DHSCR (3)
(3)
DHSCR (6)
DHSCR (5)
(self-reset)
*1.Only FX
PLCs support the DHSZ instruction.
3G
(4)
(5)
(6)
Operation of FX
/FX
3G
2N
[reference]
Present value
500
250
0
Y000,Y001
Y002
Y003
ON
Y004
Y005
*1. Due to the response delay at the output, the output
may not operate within the short time before the
counter's present value is reset to "0".
Processing sequence
FX
/FX
/FX
3G
1N
FX
/FX
3UC
2N
2NC
FX
1NC
DHSCS (1)
DHSCS (1)
DHSCS (2)
DHSCS (2)
DHSCR (3)
DHSCR (3)
*1
DHSZ (4)
DHSZ (4)
DHSCR (5)
DHSCR (5)
DHSCR (6)
DHSCR (6)
(self-reset)
(self-reset)
/FX
/FX
/FX
/FX
PLC
2NC
1N
1NC
1S
ON
OFF
Present value:1
ON
ON
*1
Present value:1
355
11
12
13
/
1S
14
15
16
17
18
19
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc series

Table of Contents