Fnc232~238 - And=, >, <, < >, <=, >= / Data Comparison - Mitsubishi Electric FX3G SERIES Programming Manual

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
28.2
FNC232~238 – AND=, >, <, < >, <=, >= / Data Comparison
Outline
These instructions compare numeric values, and set a contact to ON when the condition agrees.
1. Instruction format
FNC 232
D
AND=
FNC 233
D
AND>
FNC 234
D
AND<
FNC 236
D
AND<>
FNC 237
D
AND<=
FNC 238
D
AND>=
2. Set data (common among FNC232 to FNC238)
Operand Type
S
1
S
2
3. Applicable devices (common among FNC232 to FNC238)
Bit Devices
Oper-
and
System User
Type
X Y M T C S D .b KnX KnY KnM KnS
S
1
S
2
: This function is supported only in FX
658
Mnemonic
16-bit Instruction
5 steps AND=
Mnemonic
16-bit Instruction
5 steps AND>
Mnemonic
16-bit Instruction
5 steps AND<
Mnemonic
16-bit Instruction
5 steps AND<>
Mnemonic
16-bit Instruction
5 steps AND<=
Mnemonic
16-bit Instruction
5 steps AND>=
Device number storing comparison data
Device number storing comparison data
Digit Specification
/FX
3U
28.2 FNC232~238 – AND=, >, <, < >, <=, >= / Data Comparison
Operation Condition
32-bit Instruction
Continuous
Operation
Operation Condition
32-bit Instruction
Continuous
Operation
Operation Condition
32-bit Instruction
Continuous
Operation
Operation Condition
32-bit Instruction
Continuous
Operation
Operation Condition
32-bit Instruction
Continuous
Operation
Operation Condition
32-bit Instruction
Continuous
Operation
Description
Word Devices
Special
System User
Unit
T
C D R U \G
PLCs.
3UC
28 Data Comparison – FNC220 to FNC249
Mnemonic
Operation Condition
9 steps ANDD=
Mnemonic
Operation Condition
9 steps ANDD>
Mnemonic
Operation Condition
9 steps ANDD<
Mnemonic
Operation Condition
9 steps ANDD<>
Mnemonic
Operation Condition
9 steps ANDD<=
Mnemonic
Operation Condition
9 steps ANDD>=
16- or 32-bit binary
16- or 32-bit binary
Others
Con-
Real
Index
stant
Number
V
Z Modify K
H
E
Continuous
Operation
Continuous
Operation
Continuous
Operation
Continuous
Operation
Continuous
Operation
Continuous
Operation
Data Type
Charac-
Pointer
ter String
" "
P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc series

Table of Contents