FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
2. Program for the transfer destination
There is no change in programming especially for the transfer destination.
<SFC program>
X004
52
X005
3
53
4
35.2.5

Preliminary knowledge for creating step ladder programs

List of sequence instructions available between the STL instruction and RET instruction
Initial/general state relay
Branch/recombination
state relay
• The STL instruction cannot be used in interrupt programs and subroutine programs.
• When using SFC programs (STL instruction), do not drive state relays S using SET or OUT instructions in an
interrupt program.
• It is not prohibited to use jump instructions in state relays, but it is not recommended because complicated
movements will result.
*1.
MPS instruction cannot be used immediately after an STL instruction, even in a drive processing circuit.
788
<Step ladder>
Y002
X004
TRAN
X005
→ For the preliminary knowledge for creating SFC programs, refer to Subsection 35.1.7.
State relay
Drive processing
Transfer processing
STL
S52
Y002
SET
S53
LD/LDI/LDP/LDF,
AND/ANI/ANDP/ANDF,
ANB/ORB/MPS/MRD/
OR/ORI/ORP/ORF,
INV,MEP/MEF,OUT,
SET/RST,PLS/PLF
Available
Available
Available
35 SFC Program and Step Ladder
35.2 Step Ladder
<List program>
STL
S52
LD
X004
OUT
Y002
LD
X005
SET
S53
Instruction
MC/MCR
MPP
*1
Not available
Available
*1
Not available
Available
Not available
Not available