Value Range
Register, Blank UDP, None
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Guide References
5.2.2.3 Simple Remote Connection
Setting parameters assigned to Remote SIP-MLT—NAT - Keep Alive Packet
Sending Interval Time (s)
Specifies the time interval between transmissions of the Keep Alive packet.
Note
This interval must be shorter than the NAT binding time of the router. The default value is appropriate
in most cases.
This setting is available only when NAT - Keep Alive Packet Type is set to "Blank UDP".
Value Range
10–60 s
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Guide References
5.2.2.3 Simple Remote Connection
Setting parameters assigned to Remote SIP-MLT—NAT - SIP Register Expire
Time (s)
Specifies the length of time that will elapse before the current registration expires.
Note
This setting is available only when NAT - Keep Alive Packet Type is set to "Register".
Value Range
10–3600 s
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Guide References
5.2.2.3 Simple Remote Connection
9.5.1 PBX Configuration—[1-1] Configuration—Slot—Site Property—Main