38

Type designation

The type code of the drive is indicated on the type designation label, attached on a
door of the supply unit. The type code contains information on the specifications and
configuration of the drive. The first digits from left express the basic configuration
(eg, ACS800-07-0610-3). The optional selections are given thereafter, separated by
+ signs (eg, +E202). The main selections are described below.
Note: The information below is for quick reference only and does not contain all
conditions and details. For more information, refer to ACS800 Ordering Information
(code: 64556568), available through ABB representatives.
Selection
Product series
Type
Size
Voltage range
(nominal rating in bold)
+ options
I/O options
Fieldbus adapter
Application program
Degree of protection
Construction
Filters
Resistor braking
Hardware description
Alternatives
ACS800 product series
07 = cabinet-mounted
When no options are selected: IP21 (UL Type 1), main switch/
disconnector(s), 230 V auxiliary voltage, du/dt filtering (+E205), common
mode filtering (CMF) (+E208), EMC/RFI filtering for second environment
(+E210), drive control program, bottom entry/exit of cables, coated circuit
boards, set of English manuals.
Refer to Technical data: Ratings.
3 = 380/400/415 VAC
5 = 380/400/415/440/460/480/500 VAC
7 = 525/575/600/690 VAC
Refer to ACS800 Ordering Information (3AFY64556568 [English]).
B053 = IP22 (UL Type 1)
B054 = IP42 (UL Type 1)
B055 = IP54 (UL Type 12) (Not available with +C134)
B059 = IP54R (with connection to air outlet duct)
C121 = Marine construction (reinforced mechanical parts and fastening,
marking of conductors [A1], door handles, self-extinctive materials)
C129 = UL Listed (115 V AC auxiliary voltage, cable conduit entries, all
components UL listed/recognized, max. supply voltage 600 V; +F253,
+F260 and top entry of cables are standard)
C134 = CSA Approved (as +C129, with CSA approved components)
E202 = EMC/RFI filtering for first environment TN (grounded) system,
restricted (A-limits). Only for 6-pulse ACS800-07-0610-3 and -0760-5.
Requires +F253 and +F260.
E206 = Sine output filters (Not available with +C121, +C129 or +C134)
Note: du/dt filtering (+E205), common mode filtering (CMF) (+E208), and
EMC/RFI filtering for second environment (+E210) are standard
equipment.
D150 = brake choppers
D151 = brake resistors (not available in IP54 or IP54R)