FLEXLOGIC
ELEMENT
OPERANDS
Breaker Health
BKR 1 Hlth PKP
BKR 1 Hlth Trip PKP
BKR 1 Hlth Cls PKP
BKR 1 Hlth Chg PKP
BKR 1 Arc PKP A
BKR 1 Arc PKP B
BKR 1 Arc PKP C
BKR 1 Engy PKP A
BKR 1 Engy PKP B
BKR 1 Engy PKP C
BKR 1 Hlth OP Fail
BKR 1 Arc Fail
BKR 1 Charge Fail
Broken Rotor Bar
Brokn Rtr Bar PKP
Brokn Rtr Bar OP
Close Circuit Monitoring
Cls Coil Mon 1 PKP
Cls Coil Mon 1 OP
Contact Control
Cnct1 Rem Open
Cnct1 Rem Close
Cnct1 Rem Blk Open
Cnct1 Rem Blk Close
Cnct1 Rem Blk Opn By
Cnct1 Rem Blk Cls By
Critical Failure Relay
Critical Fail OP
Contact Inputs
CI # On
CI # Off
Contactor State Detection Contactor Opened
Contactor Closed
Contactor Unkwn Stat
Contactor Connected
Contactor Disconnect
Contactor Configured
Current Unbalance
Cur Unbal Alarm OP
Cur Unbal OP
Single Phasing OP
Demand
Current Dmd PKP
Current Dmd PKP A
Current Dmd PKP B
Current Dmd PKP C
RealPwr Dmd PKP
ReactvPwr Dmd PKP
ApprntPwr Dmd PKP
Digital Counters
Counter 1 HI
Counter 1 EQL
Counter 1 LO
Counter 1 at Limit
Counter 2 to Counter 16
Directional Power
DirPwr 1 Stg1 PKP
DirPwr 1 Stg2 PKP
DirPwr 1 PKP
DirPwr 1 Stg1 OP
DirPwr 1 Stg2 OP
DirPwr 1 OP
DirPwr 2
4–380
EVENT DESCRIPTION
Breaker health has picked up
Trip time of breaker health has picked up
Close time of breaker health has picked up
Spring charge time of breaker health has picked up
Arc time of phase A of breaker health has picked up
Arc time of phase B of breaker health has picked up
Arc time of phase C of breaker health has picked up
Arc energy of phase A of breaker health has picked up
Arc energy of phase B of breaker health has picked up
Arc energy of phase C of breaker health has picked up
Breaker trip or close operation has failed
Breaker arc time has failed
Spring charge time has failed
Broken Rotor Bar has picked up
Broken Rotor Bar has operated
Close Coil 1 Monitoring element has picked up.
Close Coil 1 Monitoring element has operated for an amount of time
greater than the Close Circuit Monitor Pick-up Delay Time.
Remote Open command is initiated to Contactor 1
Remote Close command is initiated to Contactor 1
The Open command to Contactor 1 is blocked
The Close command to Contactor 1 is blocked
The block open signal to Contactor 1 is bypassed
The block close signal to Contactor 1 is bypassed
The critical failure relay operated
# – any contact input number
Contactor state is detected open
Contactor state is detected closed
Closed or Open Contactor state cannot be detected
Contactor has been connected to the power system
Contactor has been detached from the power system
Contactor status contacts are configured
Current Unbalance alarm stage operates.
Current Unbalance trip stage operates.
Single Phasing operates.
At least one phase from current demand element has picked up
Phase A from current demand element has picked up
Phase B from current demand element has picked up
Phase C from current demand element has picked up
Real power demand has picked up
Reactive power demand has picked up
Apparent power demand has picked up
Digital counter 1 output is 'more than' comparison value
Digital counter 1 output is 'equal to' comparison value
Digital counter 1 output is 'less than' comparison value
Digital counter 1 reached limit
Same set of operands as for Counter 1
Stage 1 of the directional power element 1 has picked up
Stage 2 of the directional power element 1 has picked up
The directional power element has picked up
Stage 1 of the directional power element 1 has operated
Stage 2 of the directional power element 1 has operated
The directional power element has operated
The same set of operands per DirPwr 1
869 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL
CHAPTER 4: SETPOINTS