System Examples; Demo System Small - Bosch IRIS-Net User Manual

Table of Contents

Advertisement

IRIS-Net
EXTERNAL AMPLIFIER
STATE
COLLECTED ERROR
STATE

System Examples

DEMO SYSTEM SMALL

The IRIS-Net project "Demo System Small" is an example of a small EV remote amplifier system installation. This 2-way
stereo system includes the following equipment: 2x P3000RL, 2x Sx300 and 2x Sb121. This example is meant to
provide the necessary information to understand the entire set-up and configuration flexibility offered through the use
of the IRIS-Net software for such a system. The corresponding project file "Demo System Small.ds" is located in the
following directory: "\IRIS-Net\Projects\Demo System Small".
The following documentation provides information of individual IRIS-Net pages, panels and parameter windows that
have been created and/or used for the realization of this project. Additional explanations for the bitmap graphics are
provided in yellow-shaded text fields.
Layer 1: Configuration Page
Bosch Security Systems B.V.
A RCM-24 remote amplifier is capable of detecting and indicating the operational state of
other RCM-24 amps within a CAN net- work. The addresses of all amps that are to be
monitored are entered in the ADDR field, e.g. 2-4,6,11. The FAULTY field indicates the amp
addresses for which errors have been detected and the COLLECTED ERROR STATE has
been activated (red). The indicator changes to red as soon as at least one amplifier in the
list shows erroneous operation.
COLLECTED ERROR STATE is a collected fault message that combines all error types
detected for which the DETECT box had been marked. The HOLD function allows keeping
the COLLECTED ERROR STATE for later evaluation while CLEAR clears the indication after
remedying the cause of the fault.
The COLLECTED ERROR STATE indication is identical to the indication in the Amplifier
Status column within the System Check Window. The collected fault message can be
outputted via local control output and can also be used to transmit a fault message to other
power amps, where it is detected via EXTERNAL AMPLIFIER STATE.