Bosch IRIS-Net User Manual page 492

Table of Contents

Advertisement

IRIS-Net
14. Click on the Upgrade Firmware button in the DM-1 Web Interface.
15. Open the folder /Firmware/DM-1 in the installation directory of IRIS-Net.
16. Select the file NetMax_N8000-capability-update.dnt and start the update process.
17. Power cycle the N8000 or P 64 after the update has finished.
18. The DM-1 Dante Network Module can now be used.
HINT: The DM-1 Firmware Update fails if a DM-1 module with a firmware version older than V3.4.2 shall be updated
to the newest Version V3.4.3-RC2. A complete firmware update to V3.4.2 (including failsafe & capability image) has
to be done before the module is updated to the newest firmware version V3.4.3.
OM-1 Firmware Update
For updating the OM-1 firmware, use the OMNEO firmware upload tool (see directory /tools in the IRIS-Net installation
directory).
N8000 Browser Interface
The browser interface of the N8000's integrated web server is part of IRIS-Net's existing possibilities for configuring
and operating the N8000. The use of a current Internet Browser is recommended to access the N8000 browser
interface. The following Internet Browsers are qualified to fulfill this task:
Microsoft Internet Explorer
Mozilla Firefox (recommended)
HINT: Java Script and CSS have to be activated in the Internet Browser.
Enter the N8000's IP-address in the Internet Browser of your choice to access the browser interface. The Login page
appears. The following table lists the default IP address (next to other information for configuring the network) of the
NetMax N8000 System Controller.
Parameter
IP address
Subnet mask
Gateway
DHCP
LOGIN
The browser interface login page allows users to enter username and associated password, where the factory-set pass-
word corresponds to the actual firmware version installed in the N8000 (as listed in the table below). Only one user at
a time will be able to access the N8000 browser interface..
Parameter
Username
Passwort
Bosch Security Systems B.V.
Value
192.168.1.100
255.255.255.0
192.168.1.1
deactivated
firmware < V0.17.0a1
firmware >= V0.17.0a1
User Manual
DIGITAL MATRIX | en
Value
netmax
nmuser
netmax
2017.05 | 3.20 | F.01U.119.956
492