Miscellaneous User Controls

Picture

EOL User Controls

Picture
Bosch Security Systems B.V.
Name
Description
Labelled_SPEAKER
General loudspeaker with label. Possible Connections: - none -
_01
Name
Description
EOL_LED_Panel_0
The Short LED lights red if the voltage at the amplifier's output 1, 2, 3 or 4
1
is below the EOL VOLTAGE threshold set in the Supervision & Test tab of
the amplifier. Otherwise, the LED lights green.
The Open LED lights red if the current at the amplifier's output 1, 2, 3 or 4
is below the EOL CURRENT threshold set in the Supervision & Test tab of
the amplifier. Otherwise, the LED lights green.
The Zmin LED lights red at the occurrence of the load at the amplifier's
output 1, 2, 3 or 4 is to low (below the LOW THRESH set in the
Supervision & Test tab of the amplifier). Otherwise, the LED lights green.
The Zmax LED lights red at the occurrence of the load at the amplifier's
output 1, 2, 3 or 4 is to high (above the HIGH THRESH set in the
Supervision & Test tab of the amplifier). Otherwise, the LED lights green.
Possible Connections: CPS4.5, CPS4.10, CPS8.5, DSA 8405, DSA 8410,
DSA 8805
EOL_LED_Panel_0
The Short LED lights red if the voltage at the amplifier's output 5, 6, 7 or 8
2
is below the EOL VOLTAGE threshold set in the Supervision & Test tab of
the amplifier. Otherwise, the LED lights green.
The Open LED lights red if the current at the amplifier's output 5, 6, 7 or 8
is below the EOL CURRENT threshold set in the Supervision & Test tab of
the amplifier. Otherwise, the LED lights green.
The Zmin LED lights red at the occurrence of the load at the amplifier's
output 5, 6, 7 or 8 is to low (below the LOW THRESH set in the
Supervision & Test tab of the amplifier). Otherwise, the LED lights green.
The Zmax LED lights red at the occurrence of the load at the amplifier's
output 5, 6, 7 or 8 is to high (above the HIGH THRESH set in the
Supervision & Test tab of the amplifier). Otherwise, the LED lights green.
Possible Connections: CPS8.5, 8805
EOL_U_I_Load_Pa
Indicates the current voltage, current and load at the amplifier's output 1,
nel_01
2, 3 or 4. Possible Connections: CPS4.5, CPS4.10, CPS8.5, DSA 8405, DSA
8410, DSA 8805
EOL_U_I_Load_Pa
Indicates the current voltage, current and load at the amplifier's output 5,
nel_02
6, 7 or 8. Possible Connections: CPS8.5, DSA 8805