See
• page 24 for location of terminal block X41 of the drive
• page 6 (in this Update Notice) for the circuit diagram
• page 6 (in this Update Notice) for the dimensions of the ASTO-11C board
• section ASTO-11C in chapter Technical data for the technical data of the ASTO-
11C board.
Note: Maximum cable length between ASTO terminal block X2 and the drive
terminal block is restricted to 3 metres.
Connect the ASTO board as follows:
• Remove the cover of the enclosed ASTO unit by undoing the fixing screws (1).
• Ground the ASTO unit via the bottom plate of the enclosure or via terminal X1:2
or X1:4 of the ASTO board.
• Connect the cable delivered with the kit between terminal block X2 of the ASTO
board (2) and drive terminal block X41.
• Connect a cable between connector X1 of the ASTO board (3) and the 24 V
source.
• Fasten the cover of the ASTO unit back with screws.