110

Motor connection

Voltage (U
)
2
Frequency
Frequency resolution
Current
Power limit
Field weakening point
Switching frequency
Maximum recommended
motor cable length

Efficiency

Cooling

Method
Free space around the unit

Degrees of protection

AGPS-11C

Nominal input voltage
Nominal input current
Nominal frequency
Max. external fuse
X1 terminal sizes
Output voltage
Nominal output current
X2 terminal block type
Ambient temperature
Relative humidity
Dimensions (with enclosure) 167 x 128 x 52 mm (Height x Weight x Depth)
Weight (with enclosure)
Approvals
Technical data
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
0 to U
, 3-phase symmetrical, U
1
DTC mode: 0 to 3.2 · f
. Maximum frequency 300 Hz.
fwp
U
Nmains
f
=
· f
fwp
Nmotor
U
Nmotor
f
: frequency at field weakening point; U
fwp
U
: rated motor voltage; f
Nmotor
0.01 Hz
See section
IEC data or NEMA data.
Approximately 1.3 · P
cont.max
8 to 300 Hz
3 kHz (average).
300 m (984 ft). Additional restriction for units with EMC filtering (type code selections
+E202 and +E200): max. motor cable length is 100 m (328 ft). With longer cables the EMC
Directive requirements may not be fulfilled.
Approximately 97% at nominal power level
Internal fan, flow direction from bottom to top.
See chapter
Mechanical
installation.
IP20 (UL type open) and IP21 (UL type 1). IPXXD from above.
Without front cover, the unit must be protected against contact according to IP2x [see
chapter Electrical installation:
115...230 VAC ±10%
0.1 A (230 V) / 0.2 A (115 V)
50/60 Hz
16 A
2
3 x 2.5 mm
15 VDC ±0.5 V
0.4 A
JST B4P-VH
0...50°C
Max. 90%, no condensation allowed
0.75 kg
C-UL, US listed
at the field weakening point
max
: mains (input power) voltage;
Nmains
: rated motor frequency
Nmotor
Cabinet installed units (IP 00, UL type
open)].