ACS800-31/U31 specific parameters in the IGBT Supply Control Program

The signals and parameters of the IGBT Supply Control Program which are specific
to the ACS800-31 and ACS800-U31 are described in the tables below. These
parameters need not be set in a normal start-up. For more information on
parameters of the IGBT Supply Control Program, refer to IGBT Supply Control
Program Firmware Manual [3AFE68315735 (English)].

Terms and abbreviations

Term
B
C
Def.
FbEq
I
R
T.

Parameters

No.
Name/Value
16 SYSTEM CTR
INPUTS
16.15
I/O START MODE
DI2 EDGE
DI2 LEVEL
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Definition
Boolean data type
Character string data type
Default value data type
Fieldbus equivalent: the scaling between the value shown on the control
panel and the integer used in serial communication
Integer data type
Real data type
Data type (see B, C, I, R)
Description
Parameter lock, parameter back-up etc.
Selects I/O control start mode when par. 98.01 COMMAND SEL is set
to I/O.
Starts the line converter by digital input DI2 rising edge. The line
converter starts to modulate and the charging resistors will be by-
passed when the motor-side converter is started.
Starts the line converter by the level of digital input DI2. The line
converter starts to modulate and the charging resistors will be by-
passed when the line converter RMIO board is powered, its digital
input DI2 is ON and there are no faults.
Note: This selection changes the value of par. 98.01 COMMAND SEL
from the default setting MCW to I/O on the next RMIO board power-
up.
T./FbEq
Def.
B
DI2 EDGE
0
1