Selection of the network, logger,
plant data settings or the inverter
parameter settings
Parameters which cannot be
Parameters which can be modified
Restores the board
Saves the modifications made
A specific message appears in the
notifications if the following selec-
tions are made:
- Logger operation in «AP Mode»
- Automatic verification function of
the availability of a new Firmware
disabled
- Transmission of data to the Au-
rora Vision® cloud platform disa-
bled (function
- Transmission of events (anoma-
lies and errors) to the Aurora Vi-
sion® cloud platform disabled
In the Logger board, the settings relating to data collection, storage and
transmission can be viewed and modified.
modified
The first group of parameters cannot be modified:
Polling time: Inverter data sample period (more specifically, the VSN300
board reads the inverter parameters every 60 seconds)
Log Interval: Transfer interval of the data read by the VSN300 board to
the Aurora Vision® internet cloud platform (more specifically, the VSN300
board collects and sends the data every 300 seconds = 5 minutes)
Retention policy: Storage period of the data obtained from the inverter
in the internal memory of the VSN300 board In this specific case, 30 days
worth of data is archived with a "sliding window" type storage manage-
ment, i.e. the oldest data is deleted in favour of new data.
The second group of parameters can be customised:
Send Live Data to Aurora Vision: Enable/Disable the sending of data to
the Aurora Vision® cloud platform
Send Events to Aurora Vision: Enable/Disable the sending of errors to
the Aurora Vision® cloud platform
Automatic Check for FW Updates: Enable/Disable the automatic veri-
fication of the availability of a new Firmware for the VSN300 board or for
the inverter (internet connection is required).
If this function is enabled, automatic verification takes place every hour.
Enable Modbus TCP Client: Enable/Disable the «Modbus TCP Client»
function (refer to the specific section in the manual).
- 54 -
7 - Operation