DTMF-R STD Detection Time
Specifies the minimum length that a DTMF tone must be for the PBX to recognise it as a DTMF tone.
Value Range
2 ´ n (n=1–31) ms
Maintenance Console Location
9.22 PBX Configuration—[1-1] Configuration—Slot— SLC2 - Card Property
Hook Threshold PD A-law
Specifies the current threshold (A-law) for switching from Power Save mode to an active state. Please consult
your certified Panasonic dealer for more information.
Value Range
1.5–4.0 mA
Maintenance Console Location
9.22 PBX Configuration—[1-1] Configuration—Slot— SLC2 - Card Property
Hook Threshold PD Mu-law
Specifies the current threshold (μ-law) for switching from Power Save mode to an active state. Please consult
your certified Panasonic dealer for more information.
Value Range
1.5–4.0 mA
Maintenance Console Location
9.22 PBX Configuration—[1-1] Configuration—Slot— SLC2 - Card Property
9.22 PBX Configuration—[1-1] Configuration—Slot— SLC2 - Card Property