0870
f870 Block write data 1
0871
f871 Block write data 2
0875
f875 Block read data 1
0876
f876 Block read data 2
0877
f877 Block read data 3
f878 Block read data 4
0878
0879
f879 Block read data 5
0880
f880 Free notes
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Adjustment range
0: No selection
1: Communication command 1
(FA00)
2: Communication command 2
(FA20)
3: Frequency command value
(FA01)
4: Output data on the terminal
board (FA50)
5: FM analog output (FA51)
6: Motor speed command (FA13)
0: No selection
1: Status information 1 (FD01)
2: Output frequency (FD00)
3: Output current (FD03)
4: Output voltage (FD05)
5: Alarm information (FC91)
6: PID feedback value (FD22)
7: Input terminal monitor (FD06)
8: Output terminal monitor (FD07)
9: Terminal VIA monitor (FE35)
10:Terminal VIB monitor (FE36)
11:Terminal VIC monitor (FE37)
12:Input voltage (FD04)
13:Motor speed (FE90)
14:Torque (FD18)
0-65535
48
Default
Unit
Valid
setting
-
0
After reset.
-
0
After reset.
1
0
Real time
E6581913
Reference
Section
4.1.3
5.1.2
5.1.5
5.1.6
Section
7.5