Toshiba Tosvert VF-S15 Series Instruction Manual page 62

Rs485 communication function
Hide thumbs Also See for Tosvert VF-S15 Series:
Table of Contents

Advertisement

Cumulative operation time alarm monitor (FE79)
Comulative operation time alarm monitor (current status): "Communication Number FE79"
Bit
0
Fan life alarm
1
Circuit board life alarm
2
Main-circuit capacitor life alarm
3
User set alarm
4-15 (Undefined)
Note: The bit described "Undefined" is unstable. Don't use the bit for the judgment.
Output motor speed monitor (FD90, FE90)
Output motor speed monitor (current status): "Communication Number FD90" (unit: 1min
Output motor speed monitor (status immediately before the occurrence of a trip): "Communication
Number FE90" (unit: 1min
Ex.: Output motor speed monitor (during 60 Hz operation and 4 poles ( f856 = 2 : 4 poles )
... (0708H = 1800d, 1800min
The number of motor poles is selected by f856 .
The output moter speed is converted from the output frequency by the following calculation formula.
Output morter speed [min
1800 min
Computer  Inverter
(RFE90)
Alarm information (FC91)
Alarm information monitor (current status): "Communication Number FC91"
Bit
0
Over-current alarm
1
Inverter overload alarm
2
Motor overload alarm
3
Overheat alarm
4
Overvoltage alarm
5
Undervoltage alarm
6
Main module overload alarm
7
Low current alarm
8
Over-torque alarm
9
Braking resistor overload alarm
10
Cumulative operation hours
alarm
11
Option communication alarm
12
Serial communication alarm
13
Main-circuit voltage error alarm
14
Regenerative power ride-though
control
15
Stop at lower-limit frequency
operation (sleep function)
Note: The bit described "Undefined" is unstable. Don't use the bit for the judgment.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Specifications
-1
)
-1
)
-1
] = (120 x Output frequency [0.01Hz] ) ÷ poles [ f856 ]
-1
= (120 x 60.00Hz) ÷ 4 poles
Inverter  Computer
(RFE900708)
CR
Specifications
0
1
Normal
Alarm issued
Normal
Alarm issued
Normal
Alarm issued
Normal
Alarm issued
-
-
CR
0
1
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
-
Decelerating,
stopping
-
Decelerating,
stopping
61
E6581913
Remarks
-
-
-
-
-
-1
)
Remarks
(Code displayed on the panel)
c flickering
l flickering 
l flickering 
h flickering 
p flickering 
-
l flickering
-
-
-
-
 flickering
 flickering
moff flickering
Related: f302 setting
Related: f256 setting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents