Required Equipment And Cables; Table 3-1 Required Equipment And Cables - NEC Neax 2000 IVS System Manual

Message center interface (mci)
Hide thumbs Also See for Neax 2000 IVS:
Table of Contents

Advertisement

INSTALLATION

3. REQUIRED EQUIPMENT AND CABLES

Table 3-1
below shows the equipment and cables to be installed.
EQUIPMENT/CABLE
PN-AP00 Card
PN-4LC
RS RVS-15 CA-A/RS RVS-4
CA-C
RS NORM-4 CA-A
RS-232C Interface Cable
VMS*
MODEM*
Note 1: The equipment or cable marked with "*" should be provided by customer.
Note 2: When using the RS0-RS2 connector on the PN-AP00 for the MCI, the following RS-232C cable is
required:
• RS RVS-15 CA-A/RS RVS-4 CA-C: for connecting VMS directly
• RS NORM-4 CA-A: for connecting VMS via MODEM
Note 3: When using the RS3 connector on the PN-AP00 for the MCI, the RS NORM-4 CA-A and RS-232C
Interface Cable are required.
CHAPTER 3
Page 16
Revision 1.1

Table 3-1 Required Equipment and Cables

DESCRIPTION
Interface Card for MCI
Line Circuit Card for VMS
Connecting cable between PN-AP00 and VMS
Connecting cable between PN-AP00 and MO-
DEM/RS-232C Interface Cable
Connecting cable between RS NORM-4 CA-A
and VMS
Voice Mail System
ND-45895 (E)
Addendum-001
JULY, 1997
QUANTITY
REMARKS
1
N
1
Cable length:
15 m (49 ft.) max.
/4 m (13 ft.) max.
1
Cable length:
4 m (13 ft.) max.
1
1
2
(As required)