INSTALLATION
STEP 2: Connect the RS RVS-15 CA-A/RS RVS-4 CA-C or RS NORM-4 CA-A as shown below.
(a) When connecting a VMS directly:
Connect the VMS to the PN-AP00 using an RS RVS-15 CA-A/RS RVS-4 CA-C cable as shown in
Figure
3-9.
PBX
(PIM0-PIM7)
PN-
AP00
(b) When connecting a VMS using MODEMs, Connect the VMS through the MODEMs as shown in
Figure
3-10. In this case, the RS NORM-4 CA-A cable should be used for DCE-DCE connection.
When the cable length between the VMS and PBX is more than 15 meters (49 ft.), the MODEMs are
required.
PBX
(PIM0-PIM7)
PN-
AP00
CHAPTER 3
Page 24
Revision 1.1
RS0-RS2

Figure 3-9 RS RVS-15 CA-A/RS RVS-4 CA-C Installation

RS0-RS2
MODEM
RS NORM-4 CA-A [4m (13 ft.)]
(See Figure 3-14)

Figure 3-10 Connection of VMS with MODEMs

ND-45895 (E)
Addendum-001
JULY, 1997
RS RVS-15 CA-A [15m (49 ft.)] / RS RVS-4 CA-C [4m (13 ft.)]
(See Figure 3-13)
MODEM
2P
VMS
VMS