■Wiring diagram and parameter settings
Wire the light curtain, laser scanner, and electromagnetic contactor to safety remote I/O module of safety programmable
controllers (1) to (3) as follows. For details on the terminal block, refer to the following.
 CC-Link IE Field Network Remote I/O Module (With Safety Functions) User's Manual
Optical transmitter
24VDC
24VDC
0V
FG
Synchronization -
Optical receiver
Synchronization +
Synchronization +
Synchronization -
DC24V
Control output 1
FG
Control output 2
Light
0V
curtain*
1
Double
wired
24VDC
Control output 1
Control output 2
Laser
scanner*
2
Double
wired
Electromagnetic
[1]
contactor*
[3]
[2]
Electromagnetic contactor*
[4]
Network number 2, 3, or 4 is placed to A.
Above [1] to [4] are connected to the one with same numbers.
*1 Connect two points (PNP output) of the Type 4 light curtain control output to between input and COM.
*2 Connect two points (PNP output) of the Type 3 laser scanner control output to between input and COM.
*3 Use two electromagnetic contactors operatable by 24VDC and 0.5A.
*4 Connect normally closed contact of the electromagnetic contactor between the input terminal and test pulse terminal.
CCIEF remote (A-1)
NZ2GFSS2-32D
Network No.A (A = 2, 3, 4)
Station No.1
24VDC
A1
+24V
A2
+24V
A3
24G
A4
24G
A5
FG
24VDC
19
IO24V
20
IO24G
[1]
3
X2
[2]
4
X3
5
X4
6
X5
7
X6
8
X7
[3]
23
T0
[4]
24
T1
60
COM-
CCIEF remote (A-1)
NZ2EXSS2-8TE
Network No.A (A = 2, 3, 4)
Station No.1
3
*
4
L3
24VDC
L2
19
IO24V
L1
20
IO24G
1
Y0
2
COM-
3
Y1
4
COM-
3
*
4
Terminal block for power supply and FG (input)
A1
A2
A3
A4
A5
Spring clamp terminal block (input)
Spring clamp terminal block (output)
5 SAFETY APPLICATION CONFIGURATION EXAMPLES
5.2 System to Which Multiple Safety CPUs are Connected
+24V
+24V
24G
24G
FG
191
5