Mitsubishi Electric MELSEC iQ-R Series Safety Manual page 222

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Wiring diagram and parameter settings
Wire the safety switch and electromagnetic contactor to safety remote I/O module of safety programmable controllers (1) to
(3) as follows. For details on the terminal block, refer to the following.
 CC-Link IE Field Network Remote I/O Module (With Safety Functions) User's Manual
Guard
open/
close
Safety switch
1
2NC*
[5] [6]
[1]
[3]
[2]
[4]
Network number 2, 3, or 4 is placed to A.
Above [1] to [6] are connected to the one with same numbers.
*1 Wire a safety switch having two normally closed contacts with direct opening action to input terminal and test pulse terminal, using a
guard switch with an interlock.
*2 Use two electromagnetic contactors operatable by 24VDC and 0.5A.
*3 Connect normally closed contact of the electromagnetic contactor between the input terminal and test pulse terminal.
5 SAFETY APPLICATION CONFIGURATION EXAMPLES
220
5.2 System to Which Multiple Safety CPUs are Connected
24VDC
24VDC
Guard unlock
Open
Guard
Electromagnetic
contactor*
2
*
3
L3
24VDC
L2
L1
Electromagnetic
contactor*
2
*
3
CCIEF remote (A-1)
NZ2GFSS2-32D
Network No.A (A = 2, 3, 4)
Station No.1
A1
+24V
A2
+24V
A3
24G
A4
24G
A5
FG
19
IO24V
20
IO24G
[1]
3
X2
[2]
4
X3
5
X4
6
X5
[3]
23
T0
[4]
24
T1
25
T0
26
T1
CCIEF remote (A-1)
NZ2EXSS2-8TE
Network No.A (A = 2, 3, 4)
Station No.1
19
IO24V
20
IO24G
1
Y0
2
COM-
3
Y1
4
COM-
5
Y2
[5]
6
COM-
[6]
Terminal block for power supply and FG (input)
A1
+24V
A2
+24V
A3
24G
A4
24G
A5
FG
Spring clamp terminal block (input)
Spring clamp terminal block (output)

Advertisement

Table of Contents
loading

Table of Contents