The default counter event buffer size is set 30. The counter event mode is set to Most Recent, only most recent event
for each point is stored.
Counters are by default returned in a class zero interrogation.
Note, not all points listed here apply to all builds of devices.
Counters
Static (Steady-State) Object Number: 20
Change Event Object Number: 22
Static Variation reported when variation 0 requested: 1 (32-Bit Counter with Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Counter Event with Flag)
Frozen Counters
Static (Steady-State) Object Number: 21
Change Event Object Number: 23
Static Variation reported when variation 0 requested: 1 (32-Bit Frozen Counter with Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Frozen Counter Event with Flag)
Point
Description
Index
0 Waveform Records
1 Fault Records
2 Event Records
3 Data Log Records
5 StartCount
6 Start Count Target
7 Active Setting Group
11 CB Total Trip Count
12 CB Ph A Trip Count
13 CB Ph B Trip Count
14 CB Ph C Trip Count
15 CB E/F Trip Count
16 CB Delta Trip Count
17 CB Count To AR Block
18 CB Frequent Ops Count
21 E1 Counter
22 E2 Counter
23 E3 Counter
24 E4 Counter
Chapter 4 - Page 78 of 96
or 2 (16-Bit Counter with Flag)
or 5 (32-Bit Counter w/o Flag)
or 6 (16-Bit Counter w/o Flag)
or 2 (16-Bit Counter Event with Flag)
or 5 (32-Bit Counter Event with Flag and Time)
or 6 (16-Bit Counter Event with Flag and Time)
or 2 (16-Bit Frozen Counter with Flag)
or 5 (32-Bit Frozen Counter with Flag and Time)
or 6 (16-Bit Frozen Counter with Flag and Time)
or 9 (32-Bit Frozen Counter w/o Flag)
or 10 (16-Bit Frozen Counter w/o Flag)
or 2 (16-Bit Frozen Counter Event with Flag)
or 5 (32-Bit Frozen Counter Event with Flag and Time)
or 6 (16-Bit Frozen Counter Event with Flag and Time)
Counter
Default
Change
Default
Default
Event
Variation
Variation
Assigned
Static
Event
Class
Object 20
Object 22
(1, 2, 3
or none)
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
0,3
5
1
5
1
0,3
0,3
5
1
0,3
5
1
5
1
0,3
5
1
0,3
0,3
5
1
5
1
0,3
5
1
0,3
5
1
0,3
0,3
5
1
0,3
5
1
Frozen Counter
Default
Change
Default
Event
Variation
Assigned
Static
Class
Object 21
(1, 2, 3
or none)
1
0,2
1
0,2
1
0,2
1
0,2
1 ✔ ✔
0,2
1
0,2
1
0,2
1 ✔ ✔
0,2
1 ✔ ✔
0,2
1 ✔ ✔
0,2
1 ✔ ✔
0,2
1 ✔ ✔
0,2
1 ✔ ✔
0,2
1 ✔ ✔
0,2
1 ✔ ✔
0,2
0,2
1
0,2
1
1
0,2
1
0,2
© 2017 Siemens Protection Devices Limited
Default
Variation
Event
Object 23
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1
9
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Argus 7sr22

Table of Contents