ABB TPS48-H33 Operation Manual page 58

Hide thumbs Also See for TPS48-H33:
Table of Contents

Advertisement

Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
4
Monitoring operation
4.3.5
Replacing the speed sensor
Hot speed sensor
Danger of burns. The speed sensor can reach temperatures of more than
100 °C during operation.
WARNING
Wear safety gloves when disassembling the speed sensor.
Wear safety gloves to protect against thermal hazards.
Sealing of the speed sensor
The speed sensor is designed with a sealing lip and an additional O-ring and
does not need an additional gasket for assembly.
NOTICE
Figure 11: Fitting the speed sensor
Part number
86505
Table 9: Tightening torque (86505)
Reduce the engine performance to idling and then stop the engine. Pay attention to post-
lubrication (Stopping the engine [➙ 37]).
Switch off the lubricating oil supply to the turbocharger.
Disconnect cable connector (86515) from speed sensor (86505).
Unscrew and remove defective speed sensor (86505).
Screw in new speed sensor (86505) as far as it will go and tighten.
Connect cable connector (86515) to speed sensor (86505).
Switch on lubricating oil supply to the turbocharger.
© Copyright 2016 ABB. All rights reserved.
TPS44
M12 x 1.5
15 Nm
HZTL4037_EN
TPS48
M12 x 1.5
15 Nm
Revision A
Page 28 / 99
TPS52
M12 x 1.5
15 Nm