Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
6
Stopping the engine
6
Stopping the engine
Water-cooled turbocharger variant
Post-lubricate as long as the rotor is turning.
Observe the oil pressure while performing post-lubrication: 0.5 < p
Switch off post-lubrication as soon as the rotor has come to a standstill.
Deviating procedures must be coordinated with ABB Turbo Systems.
Water cooling after stopping the engine
If the heat in the turbocharger is not dissipated after the engine stops, dam-
age may result.
CAUTION
Allow the water cooling of the turbocharger to continue operating for 15 to
20 minutes after stopping the engine.
© Copyright 2016 ABB. All rights reserved.
HZTL4037_EN
Page 37 / 99
≤1.0.
oil
Revision A
August 2016