ABB TPS48-H33 Operation Manual page 75

Hide thumbs Also See for TPS48-H33:
Table of Contents

Advertisement

Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
7
Periodic maintenance work
7.2.5
Cartridge group, general
Corrosion
If the cartridge group is not put back into operation immediately after clean-
ing, parts may corrode.
CAUTION
Immediately after cleaning, install the cartridge group and put it back into
operation.
There can be severe contamination of the compressor wheels due to badly filtered suction air
and of the turbines because of heavy fuel oil operation or carbonized oil. Cleaning during op-
eration may not suffice to remove such contamination; instead, it may need to be cleaned me-
chanically during standard service intervals (see chapter service work).
Remove turbocharger from engine (see chapter Removing and Installing [➙ 11]).
Remove cartridge group (see chapter Dismantling and fitting [➙ 59]).
First clean the compressor end and then the turbine end according to the following description.
© Copyright 2016 ABB. All rights reserved.