System connection diagram

System connection configuration

• The unit can be connected to a CCU, remote camera, or camera recorder via a serial connection or IP connection.
• Up to 19 CCUs, remote cameras or camera recorders can be controlled.
• With a serial connection, only one of either a CCU or remote camera can be connected.
It is not possible to use a CCU serial connection and a remote camera serial connection at the same time.
• A configuration with one serial connection and 18 IP connections is possible.
• The ROP setup software provided with this unit must be installed on a personal computer and configured in order to use IP connection with CCUs,
remote cameras, and camera recorders. For details on ROP Setup Software, refer to Operations and Settings.
Please make sure that the version of the ROP setup software is Ver. 3.0.0.0 or higher when making IP connection to a camera recorder.
Operation
Connection configuration
mode
*
1
Serial
Configuration with CCU connected with a
connection
serial connection
mode
Configuration with remote camera
connected with a serial connection
Configuration with camera recorder
connected with a serial connection
IP
Configuration with IP connections only
connection
mode
Configuration with a combination of a
CCU connected with a serial connection
and CCUs and remote cameras
connected with IP connections
Configuration with a combination of a
remote camera connected with a serial
connection and CCUs and remote
cameras connected with IP connections
Configuration with camera recorder
connected with a combination of a serial
connection and IP connection
*
1
For details on operation modes, refer to Operations and Settings.

CCU connections

„ Serial (ROP cable) connection
Connection example:
AK-HCU200
12V
IN
LAN
AK-HRP200
CCU
(1 device only)
(Connection not
possible)
(Connection not
possible)
(Do not connect)
(1 device only)
(Connection not
possible)
(Connection not
possible)
ROP cable
RS-422
PREVIEW
CCU
SIGNAL GND
Serial connection
Remote camera
Camera recorder
(Connection not
(Connection not
possible)
possible)
(Connection not
(1 device only)
possible)
(Connection not
possible)
(1 device only)
(Do not connect)
(Do not connect)
(Connection not
(Connection not
possible)
possible)
(Connection not
(1 device only)
possible)
(Connection not
possible)
(1 device only)
1.
Connect the CCU connector on this unit to the ROP
connector on the CCU rear panel using a dedicated ROP
cable (sold separately).
2.
After having connected all the components, turn the CCU
main power on, and then turn the camera on.
<Note>
• If no camera is connected, the number of CCU functions that this unit
can control is limited.
• Turn off the CCU before disconnecting the ROP cable.
Use of
IP connection
ROP Setup
Software
(Do not connect)
Not required
(Do not connect)
(Do not connect)
Required
(Total of up to 19
devices)
(Total of up to 18
devices)
(Total of up to 18
devices)
(Total of up to 18
devices)
35