9.15 Control Panel ASSY

(1) Release the three hooks on the tilt hook stopper and remove the stopper.
(2) Remove the screw (TAPTITE CUP S M3x6) to release the panel grounding wire.
(3) Disconnect the panel flat cable.
Tilt hook stopper
Hooks
Hook
TAPTITE CUP S M3 x 6
Panel grounding wire
(Front)
Panel flat cable
(3_049_E)