3.3

Communications Error

Code 1
Code 2
10
10
11
11
11
11
11
11
11
11
13
16
17
20
20
20
20
20
20
20
20
20
20
20
20
20
20
07
No paper when document transmission is called
08
Wrong fax number sent
01
No dial tone detected before start of dialing
02
Busy tone detected before dialing
03
2nd dial tone not detected
05
No loop current detected
06
Busy tone detected after dialing or called
07
No response from the calling station in sending
10
Unobtainable tone detected after dialing
11
No response after sending Fax2 net command
NG response signal is received after sending Fax2 net
12
command
09
Cipher key not registered
07
No response from the calling station in receiving
01
Unable to detect a flag field
02
Carrier termination lasts for 200 msec
03
Termination command (consecutive "1" of 7 bits or more)
04
Overrun detected
05
A frame for 3 seconds or more received
06
CRC error in answerback
07
Echo command received
08
Invalid command received
Command ignored once for document setting or for dumping-
09
out at turn-around transmission
0A
T5 time-out error
0B
CRP received
0C
EOR and NULL received
While command send bit of FIF in ON, no corresponding
0D
command is received
0E
EORCommand received
Cause
2-17
Refer to
page:
Section
4.9.3
"A
communicat
ions error
occurs"