Functions; Terminals And Their Functions - Siemens 3TK2810-1 System Manual

Safety relays, safety-related speed monitor, industrial controls
Hide thumbs Also See for 3TK2810-1:
Table of Contents

Advertisement

Functions

3.1

Terminals and their functions

Supply voltage A1, A2
Connection for device supply (see Chapter "Technical data (Page 63)").
Measuring inputs U, GND, (or U1, U2), E1, E2 and RJ45
The connections E1 and E2 are provided for NPN and PNP proximity switches (device
version with NAMUR sensors). The switches are supplied by terminals U with 24 V DC
(device version NAMUR U1 = U2 = 8.2 V DC) and GND. The encoder type (NPN or PNP)
must be selected in the menu.
The RJ45 interface is suitable for connecting encoders with sin/cos, TTL and HTL signals.
Output circuits (contacts) 13/14, 23/24
The device has two output circuits each implemented with two safety relays (standstill 13/14:
K1, K2; setup or automatic speed monitoring 23/24: K3, K4) with positively-driven contacts
switched in series.
● Automatic mode: Monitoring of automatic speed window and standstill speed.
● Setup mode: Monitoring of setup speed window. Standstill permanently enabled.
● Contact 13/14 switches in if the speed drops below the set standstill speed (n < n
other words, if standstill is detected.
● Contact 23/24 switches in if the speed is within the set speed limits of setup or automatic
mode (n
Signaling outputs 15 and 25
The semiconductor signal outputs 15 and 25 are designed, for example, for connection to a
PLC and not for use in safety-related functions.
They function as follows:
● The internal supply potential (U
drops below the set standstill speed (n < n
● The internal supply potential (U
within the set speed limits of setup and automatic mode (n
3TK2810-1 safety-related speed monitor
System Manual, 01/2011, 926246402000 DS 02
< n < n
).
min
max
approx. 24 V) is output via terminal 15 when the speed
Rel
), in other words, if standstill is detected.
Still
approx. 24 V) is output via terminal 25 if the speed is
Rel
< n < n
).
min
max
3
), in
Still
23