3.3
Function diagram for automatic mode
Requirements
● Start type: Manual start
● Protective door closed and signal present at P1 and P2
● Magnet of the tumbler provides positive checkback signal (signal to MAG)
● "AUTOMATIC MODE" is selected (no signal at EA1 and signal at EA2)
13/14 and 15
23/24 and 25
3TK2810-1 safety-related speed monitor
System Manual, 01/2011, 926246402000 DS 02
max n1
AUTO
min n2
STANDSTILL
n5
start
Start
override
3.3 Function diagram for automatic mode
Functions
27