Table 6- 16
Table 6- 17
Chassis power units
Manual, (GH3), 10/2008, 6SL3097-2AE00-0BP3
Max. pulse frequency when a dv/dt filter is used in units with a rated
pulse frequency of 2 kHz
Order no.
Power
6SL3320-...
[kW]
1TE32-1AA0
110
1TE32-6AA0
132
1TE33-1AA0
160
1TE33-8AA0
200
1TE35-0AA0
250
Max. pulse frequency when a dv/dt filter is used in units with a rated
pulse frequency of 1.25 kHz
Order no.
Power
6SL3320-...
[kW]
1TE36-1AA0
315
1TE37-5AA0
400
1TE38-4AA0
450
1TE41-0AA0
560
1TE41-2AA0
710
1TE41-4AA0
800
1TG28-5AA0
75
1TG31-0AA0
90
1TG31-2AA0
110
1TG31-5AA0
132
1TG31-8AA0
160
1TG32-2AA0
200
1TG32-6AA0
250
1TG33-3AA0
315
1TG34-1AA0
400
1TG34-7AA0
450
1TG35-8AA0
560
1TG37-4AA0
710
1TG38-1AA0
800
1TG38-8AA0
900
1TG41-0AA0
1000
1TG41-3AA0
1200
Output current for a
pulse frequency of 2 kHz [A]
Connection voltage 510 – 720 V DC
210
260
310
380
490
Output current for a
pulse frequency of 1.25 kHz [A]
Connection voltage 510 – 720 V DC
605
745
840
985
1260
1405
Connection voltage 675 – 1035 V DC
85
100
120
150
175
215
260
330
410
465
575
735
810
910
1025
1270
Motor-side power components
6.3 dv/dt filter plus Voltage Peak Limiter
Max. pulse frequency when a
dv/dt filter is used
Max. pulse frequency when a
dv/dt filter is used
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
225