Table 6- 29
Technical specifications for the dv/dt filter plus Voltage Peak Limiter, 3-ph. 500 V – 690 V AC, Part 4
Order number
Suitable for Motor Module
Unit rating of the Motor
Module
I
thmax
Degree of protection
dv/dt reactor
Power loss, typical
Connections
- to the Motor Module
- load
- PE
Max. permissible cable
length between dv/dt
reactor and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage Peak Limiter
Power loss, typical
Connections
- to the dv/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Two dv/dt reactors are required for these dv/dt filters. The technical specifications provided apply to one dv/dt reactor.
1)
Note
For versions with two dv/dt reactors, the cable lengths specified in the table do not change.
Chassis power units
Manual, (GH3), 10/2008, 6SL3097-2AE00-0BP3
6SL3000-
2DH38-1AA0
6SL3320-
1TG38-1AA0
kW
800
A
810
IP00
kW
0.693
2 x M12
2 x M12
M6
m
mm
445
mm
385
mm
312
kg
160
kW
0.106
M10
M10
M8
mm
309
mm
1312.5
mm
400
kg
72
6.3 dv/dt filter plus Voltage Peak Limiter
2DH41-3AA0
1)
1)
1TG38-8AA0
900
1270
IP00
0.715
2 x M12
2 x M12
M6
300 (shielded)
450 (unshielded)
445
385
312
164
0.15
M10
M10
M8
309
1312.5
400
72
Motor-side power components
2DH41-3AA0
2DH41-3AA0
1)
1TG41-0AA0
1TG41-3AA0
1000
1270
IP00
0.715
2 x M12
2 x M12
2 x M12
2 x M12
M6
445
385
312
164
0.15
M10
M10
M8
309
1312.5
1312.5
400
72
1)
1200
1270
IP00
0.715
M6
445
385
312
164
0.15
M10
M10
M8
309
400
72
243