5.1.4.3
Installing the Braking Module in a Smart Line Module / Active Line Module / Motor
Module, frame size HX
Figure 5-10
Installing the Braking Module
The steps for the installation procedure are numbered in accordance with the diagram in
front of them.
1. Insert the Braking Module.
2. Tighten the 4 retaining screws for the Braking Module.
3. Install the connection bracket for the DC link (DCPA/DCNA).
CAUTION
The tightening torques specified in the table "Tightening torques for connecting current-
conducting parts" must be observed.
Chassis power units
Manual, (GH3), 10/2008, 6SL3097-2AE00-0BP3
Installing the Braking Module in a Smart Line Module / Active Line Module / Motor
Module, frame size HX
DC link components
5.1 Braking Module