Installing The Braking Module In A Smart Line Module / Active Line Module / Motor Module, Frame Size Hx - Siemens SINAMICS S120 Manual

Air-cooled chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.1.4.3
Installing the Braking Module in a Smart Line Module / Active Line Module / Motor
Module, frame size HX
Figure 7-10
Installing the Braking Module
The steps for the installation procedure are numbered in accordance with the diagram.
1. Insert the Braking Module.
2. Tighten the 4 retaining screws for the Braking Module.
3. Secure the connection clip to the DC link (DCPA/DCNA) with two screws (Braking Module
connection) and two nuts (DC-link connection).
Note
Pay attention to the tightening torques
The tightening torques specified in the table "Tightening torques for screw connections" must
be observed.
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3
Installing the Braking Module in a Smart Line Module / Active Line Module / Motor
Module, frame size HX
DC link components
7.1 Braking Module
345

Advertisement

Table of Contents
loading

Table of Contents