Line-side power components
4.6 Active Interface Modules
Table 4- 30
Technical data for Active Interface Modules, 3 AC 500 V ... 690 V
Article number
Suitable for Active Line Module
Rated power of Active Line Module
Rated input current of the Active Line
Module
Supply voltages
- Line voltage
- Line frequency
- Electronic power supply
- Fan supply voltage
DC-link capacitance
of the drive line-up, max.
Current consumption
- Electronics current consumption
(24 V DC)
- Fan supply, 230 V AC, max.
- Max. pre-charging current (max. 3 s)
Bypass contactor
3)
Max. ambient temperature
- Without derating
- With derating
Power loss, max.
2)
- at 50 Hz 690 V
- at 60 Hz 575 V
Cooling air requirement
Line/load connection
L1, L2, L3 / U2, V2, W2
PE connection
Line/load connection
- Line connection (L1, L2, L3)
- Load connection (U2, V2, W2)
- PE connection
Degree of protection
Dimensions
- Width
- Height
- Depth
Frame size
Weight
x = 0: with KTY84 temperature sensor, x = 1: with PT1000 temperature sensor.
1)
The specified power loss is the maximum value at 100 % utilization level. The value in normal operation is lower.
2)
Bypass contactor is not included, must be provided separately.
3)
The circuit breaker is controlled by the sequence control of the Active Line Module, and it is not permissible that it is
4)
manually closed. It is therefore recommended that the circuit breaker be equipped with the 3WL9111-0BA21-0AA0 lock-
ing set.
102
6SL3300–
7TG35–8AAx
6SL3330-
7TG35-8AA3
kW
630
A
575
V
3 AC 500 –10% (-15% < 1 min) ... 3 AC 690 +10%
ACrms
Hz
V
DC
V
AC
µF
59200
A
0.17
A
4.6
A
141
3RT1476-
6AP36
° C
40
° C
55
kW
6.8
kW
6.8
m
/s
0.40
3
M12
M12 screw
mm²
4 x 240
mm²
4 x 240
mm²
2 x 240
IP00
mm
305
mm
1750
mm
544
HI
kg
390
7TG37–4AAx
7TG41–3AAx
1)
1)
1)
7TG37-4AA3
7TG41-0AA3
800
1100
735
1025
47 ... 63 Hz
24 (20.4 ... 28.8)
230 (195.5 ... 264.5)
153600
153600
0.17
0.17
4.9
4.9
141
141
3RT1476-
3WL1212-
6AP36 (3 x)
4BB34-4AN2-Z
Z=C22
40
40
55
55
9.0
9.2
9.0
9.2
0.40
0.40
Flat connector for screw
M12
M12
M12 screw
M12 screw
6 x 240
6 x 240
6 x 240
6 x 240
4 x 240
4 x 240
IP00
IP00
505
505
1750
1750
544
544
JI
JI
430
530
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3
7TG41–3AAx
1)
7TG41-3AA3
1400
1270
153600
0.17
4.9
141
3WL1216-
4BB34-4AN2-Z
Z=C22
4)
4)
40
55
9.6
9.6
0.40
M12
M12 screw
6 x 240
6 x 240
4 x 240
IP00
505
1750
544
JI
530
Air-cooled chassis power units

Advertisement

Table of Contents
loading

Table of Contents