Active Line Modules Chassis-2; Description - Siemens SINAMICS S120 Manual

Air-cooled chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Line Modules

5.5 Active Line Modules Chassis-2

5.5
Active Line Modules Chassis-2
5.5.1

Description

The self-commutating infeed / regenerative feedback units act as step-up converters and
generate a stabilized DC link voltage that is 1.5x greater (factory setting) than the rated line
supply voltage. In this way, the connected Motor Modules are isolated from the line voltage.
This improves the dynamic response and control quality because line tolerances and
fluctuations do not affect the motor voltage.
If required, the Active Line Modules can also provide reactive power compensation.
Figure 5-41
216
Active Line Module Chassis-2, frame size FS4
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3