Air-cooled chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules
6.1 Motor Modules Chassis
Article number
Rated pulse frequency
- Max. pulse frequency without derating
- Max. pulse frequency with derating
Max. ambient temperature
- Without derating
- With derating
DC-link capacitance
Current consumption
- Electronics current consumption (24 VDC)
- Fan supply, at 2 AC 400 V, 50/60 Hz
Power loss, max.
3)
- at 50 Hz 400 V
- at 60 Hz 460 V
Cooling air requirement
Sound pressure level
L
(1 m) at 50/60 Hz
pA
Connections
- DC-link connection
- Motor connection
- PE connection PE1
- PE connection PE2
Max. conductor cross-sections
- DC-link connection (DCP, DCN)
- Motor connection (U2, V2, W2)
- PE connection PE1
- PE connection PE2
Motor cable length, max.
- shielded
- unshielded
Degree of protection
Dimensions
- Width
- Height
- Depth
Frame size
Weight
Rated power of a typical 6-pole standard induction motor based on I
1)
Rated power of a typical 6-pole standard induction motor based on I
2)
The specified power loss is the maximum value at 100% capacity utilization. The value in normal operation is lower.
3)
When used in the TN system and infeed via Active Line Module and when operating the Motor Modules with increased
4)
pulse frequency, you will receive the permitted motor cable lengths upon request.
274
6SL3320–
kHz
kHz
kHz
° C
° C
μF
A
A
kW
kW
m
/s
3
dB(A)
mm²
mm²
mm²
mm²
4)
m
m
mm
mm
mm
kg
1TE32–1AA3
1TE32–6AA3
2
2
2
2
8
8
40
40
55
55
4200
5200
0.8
0.8
0.63 / 0.95
1.13 / 1.7
1.86
2.5
1.94
2.6
0.17
0.23
64 / 67
71 / 71
M10
M10
M10
M10
M10
M10
M10
M10
2 x 185
2 x 185
2 x 185
2 x 185
2 x 185
2 x 185
2 x 185
2 x 185
300
300
450
450
IP20
IP20
326
326
1400
1400
356
356
FX
FX
95
95
or I
at 3 AC 400 V 50 Hz.
L
H
or I
at 3 AC 460 V 60 Hz.
L
H
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3
1TE33–1AA3
1TE33–8AA3
2
2
2
2
8
8
40
40
55
55
6300
7800
0.9
0.9
1.8 / 2.7
1.8 / 2.7
2.96
3.67
3.1
3.8
0.36
0.36
69 / 73
69 / 73
M10
M10
M10
M10
M10
M10
M10
M10
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
2 x 240
300
300
450
450
IP20
IP20
326
326
1533
1533
545
545
GX
GX
136
136
Air-cooled chassis power units

Advertisement

Table of Contents
loading