X9 Terminal Strip; Dcps, Dcns Connection For A Dv/Dt Filter; X41 Ep Terminal / Temperature Sensor Connection - Siemens SINAMICS S120 Equipment Manual

Chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

4.3.4

X9 terminal strip

Table 4- 3
X9 terminal strip
Terminal
1
2
3
4
5
6
L1
L2
Max. connectable cross-section: Terminals 1 – 6: 1.5 mm
4.3.5

DCPS, DCNS connection for a dv/dt filter

Table 4- 4
With frame sizes FX and GX, the connecting cables are routed down through the Motor Module and
out.
4.3.6

X41 EP terminal / temperature sensor connection

Table 4- 5
Terminal strip X41, with order numbers 6SL3320–1Txxx–xAA3
Terminal
1
2
3
4
Max. connectable cross-section 1.5 mm
Chassis power units
Manual, (GH3), 10/2008, 6SL3097-2AE00-0BP3
Signal name
P24V
M
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Connection for fan supply
(frames sizes HX and JX only)
DCPS, DCNS
Frame size
FX
GX
HX
JX
Function
EP M1 (enable pulses)
EP +24 V (enable pulses)
- Temp
+ Temp
2
Technical specifications
Voltage: 24 V DC (20.4 V – 28.8 V)
Power consumption: max. 1.4 A
380 V to 480 V AC / 500 V to 690 V AC
Power consumption: See technical specifications
, Terminals L1 - L2: 35 mm
2
Connectable cross-section
1 x 35 mm²
1 x 70 mm²
1 x 185 mm²
2 x 185 mm²
Technical data
Supply voltage: 24 VDC (20.4 V – 28.8 V)
Power consumption: 10 mA
Signal propagation delay times:
L → H 100 μs
H → L: 1000 μs
The pulse inhibit function is only available when Safety
Integrated Basic Functions are enabled.
Temperature sensor connection KTY84-1C130/PTC /
PT100
Motor Modules
4.3 Interface description
2
Terminal screw
M8
M8
M10
M10
153