Document Revision 1
4.2
E
S
5
NVIRONMENTAL
ECTION
5.1
5.2
5.3
5 - 6
Power Supply Consumption
KSU
Basic KSU – B64-U20 KSU
Basic KSU + Expansion KSU
Basic KSU + 2 Expansion KSUs
When replacing fuses, refer to the specifications in
Replacement.
Unit
Number
P64-U( ) PSU
F1
P64-U( ) PSU
F101
All fuses are normal blown glass tube.
Do not use slow blow fuses. Replace with a fuse of the
same type and rating.
C
ONDITIONS
Temperature
Operating: +32°F ~ +104°F (0°C ~ 40°C)
H
Recommended Long Term: +50°F ~ +90°F (10°C ~ 32.2°C)
H
Humidity
Operating: 10% ~ 90% noncondensing
H
Weights and Dimensions
Table 5-9 Weights and Dimensions
units, ETUs and KSUs.
Table 5-7 Power Consumption
Maximum
RMS
Current
2.5 A
5.0 A
7.5 A
Table 5-8 Fuse Replacement
Fuse
Specifications
125V, 6.0A
250V, 10A
provides weights and dimensions for the
Electra Elite IPK II
Watts Used
Watts Used
(Idle)
(Maximum)
120
230
240
460
360
690
Table 5-8 Fuse
Description
Dimensions
AC Input
1/4" x 1 1/4"
Battery Input
1/4" x 1 1/4"
Hardware Specifications