Power Supply Consumption; Environmental Conditions; Temperature And Humidity - NEC Univerge SV8100 System Hardware Manual

Full-featured ip based communications system
Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
5.3
2 - 20
KWh @ AC Input I x 230V/1000: Base chassis=0.265 KWh,
Expansion chassis=0.265 KWh, total 1.060 KWh
BTU (KWh x 3413): Base chassis=
, total
BTU
3616 BTU
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).
Dedicated 230 Vac
50/60 Hz circuit located within seven feet of the chassis
Dedicated 15A circuit
Single Phase
A dedicated outlet, separately fused and grounded for each chassis
should be installed
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).
5.2.2

Power Supply Consumption

Chassis
Basic Chassis – CD-CP00 Chassis
Basic Chassis + Expansion Chassis
Basic Chassis + 2 Expansion Chassis
Basic Chassis + 3 Expansion Chassis

Environmental Conditions

5.3.1

Temperature and Humidity

Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature: -20°C ~ 60°C
Operating Humidity: 10 ~ 90% RH (non-condensing)
904 BTU
Table 2-16 Power Consumption
Maximum
RMS
Current
1.15 A
2.3 A
3.45 A
4.6 A
UNIVERGE SV8100
, Expansion chassis=
Watts Used
Watts Used
(Idle)
(Maximum)
130
96
192
288
384
520
SV8100 System Specifications
904
260
390

Advertisement

Table of Contents
loading