Installation - NEC Univerge SV8100 System Hardware Manual

Full-featured ip based communications system
Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
4 - 80
Basic PRI Call Control (BCC)
Display of incoming caller's name and number (when allowed by the
telco)
Speech and 3.1 KHz audio
When installed, CD-PRTA uses the first block of 32 consecutive trunk
ports. For example, if a COIU blade is installed for trunks 1~8, the
CD-PRTA automatically uses trunks 9~40. If the COIU blades are
installed for trunks 1~8 and 17~24, CD-PRTA uses trunks 25~56.
The CD-PRTA cannot use trunks 9~16 (even if available) since they
are not part of a consecutive block of 32 trunks. Each CD-PRTA
requires 32 ports in the system, even if not all the ports are used,
otherwise the blade does not function.
The CD-PRTA requires one universal slot.
Table 4-44 CD-PRTA Maximum Upgrade Capacities
maximum capacities for the CD-PRTA blades when they are
upgraded.
Table 4-44 CD-PRTA Maximum Upgrade Capacities
19" Chassis
with CPU
3
5.6.2

Installation

To install the CD-PRTA:
1.
Plug the CD-PRTA into any universal slot on the chassis.
2.
Use Program 10-51-01 (PRI/T-1) to set the CD-PRTA blade to
either PRI.
3.
Connect the cable from the NT1 Network Termination cable to
the CN2 connector on the CD-PRTA. (Refer to
19" Chassis
19" Chassis
without CPU
3
With normal operation, LED 1 flashes green.
UNIVERGE SV8100
provides the
Networked
x4
Chassis
12
8
Figure 4-28 PRI
Installing the SV8100 Blades

Advertisement

Table of Contents
loading

Table of Contents