The 4SLIU and 8SLIU are not rated for OPX use. A 4DIOPU blade
should be used instead (it supports the analog DID and single line
telephone interface functions, such as Off-Premise Extensions).
One extension status LED
Two blader status LEDs
Constant current type battery feeding (25mA / -28Vdc)
Feeding Polarity Reverse Ability
Connector for PZ-4LCA/PZ-8LCE Daughter Boards
Ring Generator
Caller ID Sending Ability
Message Wait Lamping Ability
The CD-8LCA consumes eight ports ranging between ports
001~256. The CN3 and CN5 connectors each provide connection to
four analog station ports. The CNx connectors are not polarity
sensitive.
Table 4-23 CD-4LCA/CD-8LCA Maximum Upgrade Capacities
19"
SLIU
Chassis
with CPU
CD-4LCA
CD-8LCA
4.3.2

Installation

Install the CD-4LCA
slot.
19" Chassis
without CPU
5
6
5
6
When connecting a fax machine or analog
modem, make sure to set Program 15-03-03 to
1 (special terminal) to avoid communication
problems.
The SLIU and SLIDB are categorized as
TNV2. With this designation, off-premise
wiring is not acceptable. Any cabling to the
SLIU blade must be within the building – no
outside cabling is permitted.
Branch connection is not acceptable.
/
CD-8LCA blade into any available universal
Issue 1.0
19" Chassis
Networked
x4
Chassis
23
32
23
32
4 - 47