Installation

To install a PZ-ME50 on the CD-CP00:
Do not remove or install the CD-CP00 with the
power on.
For installation on the CD-CP00 blade refer to
Blade with Daughter Boards Installed on page
This daughter board does not have any switches which need to be set and does
.
not require any hardware setting.
Each node in a NetLink network requires the
PZ-ME50.
CD-CP00 without the PZ-ME50 installed,
supports a single chassis system only (Six
slots only).
CD-CP00 with the PZ-ME50 is required to
support a system with multiple chassis.
CD-CP00 without the PZ-ME50 supports
only (One) CD-LTA (8 Digital Station/2SLT)
blade.
Issue 1.0
Figure 4-4 CD-CP00
4-15.