5.3

Sequence of an acceptance test

5.3.1

Calling an acceptance test

You can test the correct mode of operation of all Safety Integrated functions using the "Safety
Acceptance" window. The results are displayed in a tabular form. Once you have successfully
tested all of the relevant functions, you can summarize the corresponding results in the form
of a report and save as RTF file.
The report of the acceptance test, supported by SINUMERIK Operate, should only be seen
as a part of the safety acceptance report for the complete machine. The report serves as basis
to be added to the results of the tests of other safety-relevant parts of the machine.
After the acceptance test has been completed, the safety acceptance report comprises 2 parts:
● Results from the Safety Integrated functions, which can be tested using SINUMERIK
Operate.
● Results from the tests of other hazardous/dangerous situations of the machine, which are
not controlled by SINAMICS.
Examples: Movement of tool changing mechanisms with the protective doors open, tool
magazines, revolvers, dressing spindles for grinding machines and/or pneumatically or
hydraulically controlled motion.
Calling an acceptance test
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
1.
Select the "Setup" operating area.
2.
Press the menu forward key and the "Safety" softkey.
3.
Press the "Acceptance test" softkey.
The acceptance test window is then displayed:
● The individual setting areas of the acceptance test are then listed in
the left-hand column.
● For each setting area, detailed settings can be made in the right-hand
column.