4.5.7

TM54F checksums

The reference and actual checksums for the master and slave are displayed in the
"Checksums" window.
Figure 4-8
Status symbols are used to flag differences between reference and actual checksums:
● Green: Reference and actual checksums are identical
● Red: Reference and actual checksums are different
The checksums are read from the SI parameters. An overview is provided below:
Master
Function
Hardware
Slave
Function
Hardware
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
Example: TM54F checksums
Actual checksum
p10005[0]
p10005[1]
p10005[0]
p10005[1]
Commissioning - TM54F
4.5 Configuring the TM54F
Reference checksum
r10004[0]
r10004[1]
r10004[0]
r10004[1]
111